Attach 22 mm adapter found in circuit bag.
Ltv 1150 ventilator circuit.
The ltv tm 1150 ventilator provides portable advanced ventilation for adult and pediatric patients at home or a post acute care facility.
The ltv 1200 1150 proprietary patient circuits are designed for maximum functionality with the ltv 1150 and 1200 ventilators.
Single patient use only.
B flow xducer flow transducer high pressure sensing port.
At only 14 lb the ventilator provides a wide range of ventilation therapies to meet demanding patient needs including volume control pressure control pressure support and spontaneous breath types.
These adult ventilator patient circuits with peep are intended to use with the ltv 900 ltv 950 and ltv 1000 ventilators utilizing external exhalation valves.
Connect the sense lines to the ltv 1200 ventilator.
Connect the circuit to the ltv 1200 ventilator.
Each adult ventilator patient circuit with peep includes.
They may also be used with the ltv 900 950 and 1000 if peep is not required.
They come 10 circuits in a pack.
Filter optional turn clockwise.
Outfront medical offers competitive rates.
D exh valve exhalation valve drive line port.
Operator s manual ltv 1150 ventilator 19159 001 rev.
For single patient use only do not soak rinse wash or sterilize them.
Contact us at 888 291 4441.
Do not soak rinse wash or sterilize them.
Box of 10 patient circuits used with the ltv1150 and ltv1200.
E alarm sounder port f cooling fan g dc input dc power port pigtail connector.
Turn on the ltv 1200 ventilator.
New part 29657 001 10 each case.
For 24 hour assistance call 800 754 1914.
These adult ventilator patient circuits without p e ep are intended to use with the ltv 1150 and ltv 1200 ventilators utilizing external exhalation valves.
10 circuits per case.
Each patient circuit includes.
Ltv series circuits ltv series 1100 1150 and 1200 ventilator circuits without peep continued spu heated wire circuits for fisher paykel humidifiers 5 5 ft 15090 102 patient circuit w o peep 22 mm spu single heated wire fisher paykel 10 pkg 1 7 m x 22 mm heated insp limb temp probe port wye and 61 cm x 22 mm exp limb 15091 102.
Connect circuit to 22 mm adapter.
Compatible with ltv ventilators the ventilator circuits are available and made to be completely compatible with the ltv 1150 and ltv 1200 ventilators.
C flow xducer flow transducer low pressure sensing port.
Pulmonetic systems warrants that the ltv 1150 ventilator is free from defects in material and workmanship for a period of one 1 year from the date of shipment or 8 800 hours as measured on the usage meter whichever comes first with the following limitations.
Ltv series ventilators are designed to be used in dynamic environments whether it.